Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Material  Insulation Material  Jacket Diameter  Applicable Specifications 
275002001 Conductor  BRAID  600  20  ETFE  ETFE  0.102  MIL-C-27500, MIL-W-22759/16 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 1 X 1 COND 
a) Conductor 20 (19/32) AWG TC 0.040
b) Insulation 0.010" Wall, Nom. ETFE 0.060
(1) Color(s)  
Cond Color Cond Color Cond Color
1 WHITE   
2) Shield TC BRAID Shield,85% Coverage, Min. 
3) Jacket 0.010" Wall, Nom.,ETFE0.102 (0.107 Max.)
a) Color(s) NATURAL
1) Other   
a) Component 1 SAE-A522759/16 
b) Overall NEMA WC 27500 TYPE TE 150°C
2) CE:EU Low Voltage Directive 2006/95/EC
1) CE: EU Directive 2011/65/EU(RoHS2):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011. No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:The outer surface materials used in the manufacture of this part meet the requirements of California Proposition 65.
Physical & Mechanical Properties
1) Temperature Range-55 to 150°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 12.8 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 600 VRMS
2) Ground Capacitance91 pf/ft @1 kHz, Nominal
3) Inductance0.04 µH/ft, Nominal
4) Conductor DCR10.5 Ω/1000ft @20°C, Nominal
5) OA Shield DCR5.6 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 100 FT 3.5 x 3 x 1.125 Continuous length
b) Bulk(Made-to-order) 
 [Spool dimensions may vary slightly]

Alpha Wire’s high/low temperature cables are available for temperatures ranging from -55°C to 200°C. Our expertise in high-temperature materials such as teflon will help you select the right cable to meet the demanding high-temperature requirements for control and power applications. 