*** alphawire.com *** master: ALPH01-DB01\DP_AlphaWire_6.5.5_Master, web: ALPH01-DB01\DP_AlphaWire_6.5.5_Web, membership: ALPH01-DB01\DP_Alphawire_Membership, Portal: ALPH01-DB01\AlphaWire_Portal, aw.js rel.20171221204330

Part # Type  Shielding  Voltage  AWG  # of Elements  Jacket Diameter  Applicable Specifications 
V16116 Conductor  FOIL_BRAID  600/1000  16+14  4.2  0.717  CA Prop 65, CE, CSA C(UL) CIC CONTROL, CSA AWM I/II A/B, CSA FT4, UL DIRECT BURIAL, UL EXPOSED RUN, UL RHW-2Wet/Dry, UL SUN RES, UL TC, UL WTTC, UL XHHW-2Wet/Dry 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 4 X 1 COND 
a) Conductor 16 (26/30) AWG Tinned Copper 0.059
b) Insulation 0.047" Wall, Nom. XLPE 0.156
(1) Separator Paper Tape, 10% Overlap, Min. 
(2) Color(s)  
Cond Color Cond Color Cond Color
1 BLACK#1 3 BLACK#3 
2 BLACK#2 4 GREEN OR GREEN/YELLOW 
2) Component 2 1 X 1 PAIR 
a) Conductor 14 (41/30) AWG Tinned Copper 0.074
b) Insulation 0.032" Wall, Nom. XLPE 0.142
(1) Separator Paper Tape, 10% Overlap, Min. 
(2) Color(s)  
Pair Color Pair Color Pair Color
1 BLACK-WHITE   
c) Pair 2/Cond Cabled Together 
(1) Twists: 2.8 Twists/foot (min) 
Individually Applied:
d) Shield: Alum/Mylar Tape, 25% Overlap, Min. 
(1) Foil Direction Foil Facing In 
(2) Drain Wire 14 (41/30) AWG Tinned Copper 
3) Cable Assembly 5 Components Cabled 
a) Twists: 1.7 Twists/foot (min) 
b) Orientation: Components to be arranged from INSIDE LAYER to OUTSIDE LAYER 
4) Shield: A/P/A Tape, 25% Overlap, Min. 
a) Drain Wire 16 (26/30) AWG Tinned Copper 
b) Braid Tinned Copper,85% Coverage, Min. 
5) Jacket 0.065" Wall, Nom.,PVC0.717+/- 0.026
a) Color(s) BLACK
b) Jacket Separator Tissue Tape, 25% Overlap, Min. 
c) Print ALPHA WIRE-* P/N V16116 4C 16 AWG 1PR 14 AWG
SHIELDED (UL) 1000V FLEXIBLE MOTOR
SUPPLY CABLE OR WTTC 90C WET/DRY OR 600V TC-ER
XHHW-2 CDRS XLPE/PVC 90C WET/DRY
OR 16 AWG C(UL) 600V CIC TC 90C WET/DRY FT4 (-25C)
--- P-07-KA080006-MSHA --- LLXXXXXX CSA AWM I/II
A/B 1000V 90C FT4 CE ROHS (SEQ FOOTAGE)
* = Factory Code
[Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.]
1) UL   
a) Component 1 RHW-2Wet/Dry 90°C Dry / 90°C Wet / 600 VRMS
 XHHW-2Wet/Dry 90°C Dry / 90°C Wet / 600 VRMS
b) Component 2 XHHW-2Wet/Dry 90°C Dry / 90°C Wet / 600 VRMS
c) Overall TC 90°C Dry / 90°C Wet / 600 VRMS
 EXPOSED RUN 
 DIRECT BURIAL 
 SUN RES 
 1000V Flexible Motor Supply Cable 
 WTTC 90°C / 1000 VRMS
2) CSA International   
a) Component 1 AWM I A/B 90°C / 1000 VRMS
b) Component 2 AWM I A/B 90°C / 1000 VRMS
c) Overall AWM I/II A/B 90°C / 1000 VRMS
 FT4 
 C(UL) TC 90°C Dry / 90°C Wet / 600 VRMS
 C(UL) CIC CONTROL 90°C Dry / 90°C Wet / 600 VRMS
 C(UL) -25C 
3) Other PMSHA Specification 
4) CE:EU Low Voltage Directive 2014/35/EU
1) CE: EU Directive 2011/65/EU(RoHS2):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
Physical & Mechanical Properties
1) Temperature Range-40 to 90°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 214 Lbs, Maximum
4) Sunlight Resistance Yes
5) Direct Burial Yes
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 1000 VRMS
2) Component 1
a) Characteristic Impedance 90 Ω
b) Inductance 0.23 µH/ft, Nominal
c) Mutual Capacitance 21 pF/ft @1 kHz, Nominal
d) Ground Capacitance 38 pF/ft @1 kHz, Nominal
e) Conductor DCR 4.4 Ω/1000ft @20°C, Nominal
f) OA Shield DCR 1.06 Ω/1000ft @20°C, Nominal
g) Current 14.4 amps per conductor @30°C, Maximum
h) Insulation Resistance 300 MΩ/MFt (Est.)
3) Component 2
a) Inductance 0.19 µH/ft, Nominal
b) Mutual Capacitance 22 pF/ft @1 kHz, Nominal
c) Ground Capacitance 40 pF/ft @1 kHz, Nominal
d) Conductor DCR 2.6 Ω/1000ft @20°C, Nominal
e) Ind. Shield DC Resistance 2.43 Ω/1000ft @20°C, Nominal
f) Current 20 amps per conductor @30°C, Maximum
g) Insulation Resistance 300 MΩ/MFt (Est.)
PackagingFlange x Traverse x Barrel (inches)
a) Bulk(Made-to-order) 

Industrial Series V (VFD):

Optimized specifically for variable-frequency drives, Alpha Wire's Series V VFD cable offers industry-leading mechanical and electrical performance.

Series V Key features:

  • 4-conductor and 3-conductor (NEW!) available
  • 16 to 4/0 AWG
  • Cross-linked polyethylene insulation
  • PVC jacket
  • Small diameter
  • Low capacitance for improved signal transmission
  • UL Type TC-ER (600 V)
  • CSA I/II A/B 1000V FT4
  • Direct burial
  • Sunlight resistant

Request a Sample Download Brochure Consult a Cable Expert