# de pieza AWG  Stranding  Construction Type  # of Elements  Shielding  Jacket Diameter  Temperature Range  Voltage  Applicable Specifications 
78302 28  19/40  COND  FOIL_BRAID  0.125  -40 to 80  300  CA Prop 65, CE, CSA - FT1, CSA AWM I A/B, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL AWM 21460, UL VW-1 
(Ctrl+Click if PDF doesn't appear)
 Diameters (In)
1) Component 1 2 X 1 COND 
a) Conductor 28 (19/40) AWG Tinned Copper 0.016
b) Insulation 0.007" Wall, Nom. Modified Polyphenylene Ether-PE 0.030
(1) Color Code Alpha Wire Color Code E
Cond Color Cond Color Cond Color
1 BLACK 2 BROWN 
2) Cable Assembly 2 Components Cabled 
a) Twists: 13.7 Twists/foot (min) 
b) Orientation: Components to be arranged from INSIDE LAYER to OUTSIDE LAYER 
c) Core Wrap Nonwoven Polyester Tape, 25% Overlap, Min. 
3) Shield: A/P/A Tape, 25% Overlap, Min. 
a) Drain Wire 28 (7/36) AWG Tinned Copper 
b) Braid Tinned Copper,70% Coverage, Min. 
4) Jacket 0.015" Wall, Nom.,Modified Polyphenylene Ether-PE0.125 (0.132 Max.)
a) Color(s) SLATE
b) Ripcord 1 End 810 Denier Nylon 
c) Jacket Separator Nonwoven Polyester Tape, 25% Overlap, Min. 
d) Print ALPHA WIRE-* P/N 78302 2C 28 AWG
ECOCABLE(R) MINI RU AWM 21460 80C 300V VW-1
C(RU) AWM I A/B FT1 80C 300V
CE ROHS (SEQ FOOTAGE)
* = Factory Code
1) UL AWM/STYLE 21460 80°C / 300 VRMS
 VW-1 
2) CSA International C(RU) AWM I A/B FT1 80°C / 300 VRMS
3) Other Halogen-Free 
 NFPA 79 - 2015 Compliant 
4) CE:EU Low Voltage Directive 2014/35/EC
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3):
 This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. Consult Alpha Wire's web site for RoHS C of C.
2) REACH Regulation (EC 1907/2006):
 This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. For up-to-date information, please see Alpha's REACH SVHC Declaration.
3) California Proposition 65:Exempt from warning labels based on the Consent Judgment. Please see Alpha's CA Prop 65 Statement for more information.
Physical & Mechanical Properties
1) Temperature Range-40 to 80°C
2) Bend Radius 10X Cable Diameter
3) Pull Tension 5.6 Lbs, Maximum
Electrical Properties(For Engineering purposes only)
1) Voltage Rating 300 VRMS
2) Capacitance 26 pF/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance47 pF/ft @1 kHz, Nominal
4) Characteristic Impedance63 Ω
5) Inductance0.19 µH/ft, Nominal
6) Conductor DCR63 Ω/1000ft @20°C, Nominal
7) OA Shield DCR11.5 Ω/1000ft @20°C, Nominal
PackagingFlange x Traverse x Barrel (inches)
a) 1000 FT 12 x 4.5 x 3.5 Continuous length
b) 100 FT 6.5 x 2 x 1.9 Continuous length
c) Bulk(Made-to-order) 
 [Spool dimensions may vary slightly]
EcoCable® Mini es la última generación de cables de 300 V. Al combinar el mejor rendimiento y el mínimo impacto medioambiental, EcoCable Mini utiliza su aislamiento y cobertura de mPPE para proporcionar todas las ventajas en un cable más pequeño y más ligero.

Características de EcoCable Mini 

  • Cobertura y aislamiento de mPPE reciclable    
  • Rango de temperatura de -40°C a +80°C
  • Cumple con RoHS y REACH
  • Adecuado para su uso en aplicaciones NFPA 79    
  • Más de 250 construcciones estándar disponibles

Beneficios de EcoCable Mini

  • Hasta 32% más pequeño que el PVC
  • Hasta 44% más ligero que el PVC
  • Hasta un 92% menos de desgasificación que los cables estándar de PVC de 300 V
  • Sin halógenos
  • 100% reciclable

Solicite una muestra Descargar el catálogo Consultar a un experto