EcoFlex®️ PUR 80033
EcoFlex®️ PUR 80033

This picture is representative only and may not match the specific configuration of the product listed on this page. Please refer to the product specifications for more information on this part number and its exact configuration.
Download RoHS Certificate
Get the abrasion, UV, and oil resistance of a tough zero-halogen Polyurethane jacket in a flex cable that’s up to 40% smaller and 44% lighter than other 600V continuous flex cables.
- Zero Halogen, contains no heavy metals or phthalates
- PUR jacket, mPPE insulation
- 8M+ flex life cycles
- finely stranded tinned copper conductors, class 6
- Up to 40% smaller and 44% lighter than standard 600V PUR continuous flex cables
- UL Oil Res I
- UL Sunlight Resistant
- Operating temperature -50C to +90C (static) and -40C to +80C (dynamic)
- Bend Radius 4X (static) and 6X (dynamic)
With its rugged PUR jacket and finely stranded conductors, EcoFlex PUR cable provides 8+ million flex cycles in tough application conditions—while saving space and reducing weight. And with a wide range of conductor sizes, conductor counts, and shielded and unshielded versions, you can find the cable you need.
Construction
Diameters (In) | ||||||||||||||
1) Component 1 | 3 X 1 COND | |||||||||||||
a) Conductor | 18 (41/34) AWG Tinned Copper | 0.043 | ||||||||||||
b) Insulation | 0.012" Wall, Nom. MPPE | 0.067 | ||||||||||||
(1) Print | ALPHANUMERIC NUMBERS - 1-ONE ALTERNATING AND INVERTED | |||||||||||||
(2) Color Code | Alpha Wire Color Code KX | |||||||||||||
| ||||||||||||||
2) Cable Assembly | 3 Components Cabled | |||||||||||||
a) Twists: | 8.0 Twists/foot (min) | |||||||||||||
b) Orientation: | Components to be arranged from INSIDE LAYER to OUTSIDE LAYER | |||||||||||||
c) Core Wrap | Nonwoven Polyester Tape, 25% Overlap, Min. | |||||||||||||
3) Jacket | 0.032" Wall, Nom.,Polyurethane, Zero Halogen (ZH) | 0.213+/- 0.010 | ||||||||||||
a) Color(s) | SLATE | |||||||||||||
b) Print | ALPHA WIRE-* P/N 80033 3C 18 AWG RU AWM STYLE 21959 90C 600V SUN RES 60C OIL OR CRU AWM I/II A/B 90C 600V FT2 --- IEC EN 60332-1/2 CE ROHS (SEQ FOOTAGE) * = Factory Code |
Applicable Specifications
1) UL | ||
a) Component 1 | AWM/STYLE 11231 | 105°C / 600 VRMS |
b) Overall | AWM/STYLE 21959 | 90°C / 600 VRMS |
60C OIL | ||
SUN RES | ||
2) CSA International | C(RU) AWM I/II A/B | 90°C / 600 VRMS |
FT2 | ||
3) IEC | ||
a) Component 1 | EN 60228 Conductors, Class 6 | |
b) Overall | EN 60754-1 Acid Gas Generation | |
EN 60754-2 Acid Gas Generation | ||
EN 60332-1 Flame Behavior | ||
EN 60332-2 Flame Behavior | ||
4) Other | NFPA 79 - 2015 Compliant | |
5) CE: | EU Low Voltage Directive 2014/35/EU |
Environmental
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3): | ||
This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. | ||
2) REACH Regulation (EC 1907/2006): | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. |
Properties
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -50 to 90°C(static), -40 to 80°C (dynamic) |
2) Bend Radius | 4X Cable Diameter(static), 6X Cable Diameter(dynamic) |
3) Pull Tension | 38 Lbs, Maximum |
4) Sunlight Resistance | Yes |
Electrical Properties | (For Engineering purposes only) |
1) Voltage Rating | 600 VRMS |
2) Capacitance | 20.5 pF/ft @1 kHz, Nominal Conductor to Conductor |
3) Inductance | 0.17 μH/ft, Nominal |
4) Conductor DCR | 6.9 Ω/1000ft @20°C, Nominal |
Other
Packaging | Flange x Traverse x Barrel (inches) |
a) 100 FT | 6.5 x 4 x 2.5 Continuous length |
b) Bulk(Made-to-order) | |
[Spool dimensions may vary slightly] |