Downtime is costly—whether caused by a complete cable failure or issues that occur when a cable does not meet the demands of its application. Alpha Wire’s Xtra-Guard TPE Flex line combines physical toughness and flex performance in one cable to ensure your peace of mind.
Construction
Diameters (In) | ||||||||||||||||||||
1) Component 1 | 5 X 1 COND | |||||||||||||||||||
a) Conductor | 16 (26/30) AWG Bare Copper | 0.060 | ||||||||||||||||||
b) Insulation | 0.016" Wall, Nom. PVC/ 0.005" Wall NYLON | 0.102 | ||||||||||||||||||
(1) Print | ALPHANUMERIC NUMBERS - 1-ONE ALTERNATING AND INVERTED | |||||||||||||||||||
(2) Color Code | Alpha Wire Color Code KX | |||||||||||||||||||
| ||||||||||||||||||||
2) Cable Assembly | 5 Components Cabled | |||||||||||||||||||
a) Twists: | 3.2 Twists/foot (min) | |||||||||||||||||||
b) Orientation: | Components to be arranged from OUTSIDE LAYER to INSIDE LAYER | |||||||||||||||||||
c) Core Wrap | Polyester Fabric Tape, 25% Overlap, Min. | |||||||||||||||||||
3) Shield | Tinned Copper BRAID Shield,85% Coverage, Min. | |||||||||||||||||||
4) Jacket | 0.050" Wall, Nom.,TPE | 0.417+/- 0.021 | ||||||||||||||||||
a) Color(s) | SLATE | |||||||||||||||||||
b) Print | ALPHA WIRE-* P/N 901605CY 5C 16 AWG (1.32mm2) (UL) TYPE TC 90C WET/DRY 600V OIL RES I/II SUN RES OR PLTC 90C OR C(UL) CIC CONTROL/TC 90C PVC/NYLON INS FT4 16 AWG OR CRU AWM I/II A/B 90C 600V FT4 CE ROHS (DATE CODE) (SEQ FOOTAGE) * = Factory Code [Note: Product may have c(UL) or CSA markings depending upon plant of manufacture.] |
Applicable Specifications
1) UL | ||
a) Component 1 | MTW | 90°C Dry / 60°C Wet / 600 VRMS |
b) Overall | TC | 90°C Dry / 90°C Wet / 600 VRMS |
SUN RES | ||
OIL RES I/II | ||
PLTC | 90°C | |
2) CSA International | C(RU) AWM I/II A/B | 90°C / 600 VRMS |
FT4 | ||
C(UL) CIC CONTROL | 90°C / 600V VRMS | |
C(UL) TC | 90°C / 600V VRMS | |
3) Other | Conductors ASTM Class K | |
4) CE: | EU Low Voltage Directive 2014/35/EU |
Environmental
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3): | ||
This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. | ||
2) REACH Regulation (EC 1907/2006): | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. | ||
3) California Proposition 65: | This product may contain substances known to the State of California to cause Cancer or Reproductive Harm, but is exempt from labeling based on the Consent Judgement. See the Alpha Wire website for more information. |
Properties
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -30 to 90°C(static), -5 to 90°C (dynamic) |
2) Bend Radius | 8X Cable Diameter(static), 8X Cable Diameter(dynamic) |
3) Pull Tension | 111 Lbs, Maximum |
4) Sunlight Resistance | Yes |
Electrical Properties | (For Engineering purposes only) |
1) Voltage Rating | 600 VRMS |
2) Capacitance | 44 pF/ft @1 kHz, Nominal Conductor to Conductor |
3) Ground Capacitance | 79 pF/ft @1 kHz, Nominal |
4) Inductance | 0.18 μH/ft, Nominal |
5) Conductor DCR | 4.1 Ω/1000ft @20°C, Nominal |
6) OA Shield DCR | 2.3 Ω/1000ft @20°C, Nominal |
Other
Packaging | Flange x Traverse x Barrel (inches) |
a) 1000 FT | 24 x 14 x 12 Continuous length |
b) 100 FT | 12 x 5.94 x 5 Continuous length |
[Spool dimensions may vary slightly] | |
Notes: | |
a) Suitable for intermittent or light duty flexing where cycle count will be less than 1,500,000 cycles. |