![XG1](https://cdn.belden.com/-/media/Images/ProductPictures/WIREC_pg35_text.jpg?h=289&iar=0&w=432&rev=f79cc1caa7df4fbab4dcef357717a05a)
Xtra-Guard 1 5517
Xtra-Guard 1 5517
![XG1](https://cdn.belden.com/-/media/Images/ProductPictures/WIREC_pg35_text.jpg?h=289&iar=0&w=432&rev=f79cc1caa7df4fbab4dcef357717a05a)
This picture is representative only and may not match the specific configuration of the product listed on this page. Please refer to the product specifications for more information on this part number and its exact configuration.
Download RoHS Certificate
Xtra-Guard® 1 - High performance in a tough PVC cable
- High-performance cable for general-purpose applications
- Features a unique, premium-grade PVC insulation and jacket for Easier routing of cable in small spaces
- Provides resistance to oils per UL Oil Res I (60C OIL RES) and Class 43
- UL SUN RES
- Designed for use in ambient temperatures up to 105 ° C
- Temperature range of -35 ° C to + 105 ° C (SR-PVC) and -30 ° C to + 105 ° C (PVC)
- Provides exceptional protection contre EMI interference When Supra-Shield is specified
Construction
Diameters (In) | ||||||||||||||||||||||||||
1) Component 1 | 7 X 1 COND | |||||||||||||||||||||||||
a) Conductor | 20 (10/30) AWG Tinned Copper | 0.037 | ||||||||||||||||||||||||
b) Insulation | 0.0325" Wall, Nom. PVC | 0.102 | ||||||||||||||||||||||||
(1) Color Code | Alpha Wire Color Code E | |||||||||||||||||||||||||
| ||||||||||||||||||||||||||
2) Cable Assembly | 7 Components Cabled | |||||||||||||||||||||||||
a) Twists: | 2.7 Twists/foot (min) | |||||||||||||||||||||||||
b) Orientation: | Components to be arranged from INSIDE LAYER to OUTSIDE LAYER | |||||||||||||||||||||||||
c) Core Wrap | Nonwoven Polyester Tape, 20% Overlap, Min. | |||||||||||||||||||||||||
3) Shield: | A/P/A Tape, 20% Overlap, Min. | |||||||||||||||||||||||||
a) Drain Wire | 20 (7/28) AWG Tinned Copper | |||||||||||||||||||||||||
b) Braid | Tinned Copper,70% Coverage, Nom. | |||||||||||||||||||||||||
4) Jacket | 0.063" Wall, Nom.,PVC | 0.466 (0.489 Max.) | ||||||||||||||||||||||||
a) Color(s) | Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White | |||||||||||||||||||||||||
b) Ripcord | 1 End 810 Denier Nylon | |||||||||||||||||||||||||
c) Print | ALPHA WIRE-* P/N 5517 7C 20 AWG XTRAGUARD(R) 1 (UL) MTW 600V OR AWM 2501 105C 600V OR AWM 21896 105C 600V SUN RES 60C OIL VW-1 OR CRU AWM I/II A/B 105C 600V FT4 CE ROHS (SEQ FOOTAGE) * = Factory Code |
Applicable Specifications
1) UL | ||
a) Component 1 | AWM/STYLE 1015 | 105°C / 600 VRMS |
MTW | 90°C Dry / 60°C Wet / 600 VRMS | |
b) Overall | MTW | 90°C Dry / 60°C Wet / 600 VRMS |
AWM/STYLE 21896 | 105°C / 600 VRMS | |
SUN RES | ||
60C OIL | ||
AWM/STYLE 2501 | 105°C / 600 VRMS | |
VW-1 | ||
2) CSA International | ||
a) Component 1 | TEW | 105°C / 600 VRMS |
b) Overall | C(RU) AWM I/II A/B | 105°C / 600 VRMS |
FT4 | ||
3) IEC | EN 60332-1 Flame Behavior | |
EN 60332-2 Flame Behavior | ||
4) CE: | EU Low Voltage Directive 2014/35/EU |
Environmental
1) CE: EU Directive 2011/65/EU(RoHS2), EU Directive 2015/863/EU (RoHS3): | ||
This product complies with European Directive 2011/65/EU (RoHS Directive) of the European Parliament and of the Council of 8 June 2011 and the amending Directive 2015/863/EU of 4 June 2015 . No Exemptions are required for RoHS Compliance on this item. | ||
2) REACH Regulation (EC 1907/2006): | ||
This product does not contain Substances of Very High Concern (SVHC) listed on the European Union's REACH candidate list in excess of 0.1% mass of the item. | ||
3) California Proposition 65: | This product may contain substances known to the State of California to cause Cancer or Reproductive Harm, but is exempt from labeling based on the Consent Judgement. See the Alpha Wire website for more information. |
Properties
Physical & Mechanical Properties | |
---|---|
1) Temperature Range | -30 to 105°C |
2) Bend Radius | 10X Cable Diameter |
3) Pull Tension | 70 Lbs, Maximum |
4) Sunlight Resistance | Yes |
Electrical Properties | (For Engineering purposes only) |
1) Voltage Rating | 600 VRMS |
2) Capacitance | 28 pF/ft @1 kHz, Nominal Conductor to Conductor |
3) Ground Capacitance | 50 pF/ft @1 kHz, Nominal |
4) Inductance | 0.24 μH/ft, Nominal |
5) Conductor DCR | 11.5 Ω/1000ft @20°C, Nominal |
6) OA Shield DCR | 2.07 Ω/1000ft @20°C, Nominal |
Other
Packaging | Flange x Traverse x Barrel (inches) |
a) 1000 FT | 24 x 14 x 12 Continuous length |
b) 500 FT | 18 x 14.25 x 8 Continuous length |
c) 100 FT | 12 x 5.94 x 5 Continuous length |
d) Bulk(Made-to-order) | |
[Spool dimensions may vary slightly] |